File:Regional-differences-in-APD-restitution-can-initiate-wavebreak-and-re-entry-in-cardiac-tissue-A-1475-925X-4-54-S1.ogv
Regional-differences-in-APD-restitution-can-initiate-wavebreak-and-re-entry-in-cardiac-tissue-A-1475-925X-4-54-S1.ogv (Ogg Theora video file, length 1 min 57 s, 320 × 240 pixels, 59 kbps, file size: 846 KB)
Captions
Summary[edit]
DescriptionRegional-differences-in-APD-restitution-can-initiate-wavebreak-and-re-entry-in-cardiac-tissue-A-1475-925X-4-54-S1.ogv |
English: Additional File 1 Figure4a.mpg Wavebreak and re-entry in the model with steep APD restitution. The S1S2 interval was 200 ms, and the S2S3 interval was 120 ms. Movie of simulation depicted in Figure 4a. |
||
Date | |||
Source | Clayton R, Taggart P (2005). "Regional differences in APD restitution can initiate wavebreak and re-entry in cardiac tissue: A computational study". BioMedical Engineering OnLine. DOI:10.1186/1475-925X-4-54. PMID 16174290. PMC: 1261529. | ||
Author | Clayton R, Taggart P | ||
Permission (Reusing this file) |
This file is licensed under the Creative Commons Attribution 2.0 Generic license.
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 02:58, 10 February 2022 | 1 min 57 s, 320 × 240 (846 KB) | Mitar (talk | contribs) | Fixed file. | |
17:31, 20 November 2012 | 0.0 s, 320 × 240 (844 KB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Transcode status
Update transcode statusMetadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Short title | Additional File 1 |
---|---|
Author | Clayton R, Taggart P |
Usage terms | http://creativecommons.org/licenses/by/2.0/ |
Image title | Figure4a.mpg Wavebreak and re-entry in the model with steep APD restitution. The S1S2 interval was 200 ms, and the S2S3 interval was 120 ms. Movie of simulation depicted in Figure 4a. |
Software used | Lavf58.29.100 |
Date and time of digitizing | 2005 |