File:Imperceptible-magnetoelectronics-ncomms7080-s4.ogv
From Wikimedia Commons, the free media repository
Jump to navigation
Jump to search
No higher resolution available.
Imperceptible-magnetoelectronics-ncomms7080-s4.ogv (Ogg multiplexed audio/video file, Theora/Vorbis, length 48 s, 640 × 480 pixels, 1 Mbps overall, file size: 5.75 MB)
File information
Structured data
Captions
Summary
[edit]DescriptionImperceptible-magnetoelectronics-ncomms7080-s4.ogv |
English: Supplementary Movie 3 Contacted magnetic field sensor on the palm and recorded resistance. This video demonstrates the compliancy of an on-skin sensor array (Co/Cu 1st maximum) attached to a human palm with one element contacted, together with its live recorded resistance. It shows that the resistance change during the motion of the hand is low compared to the change imposed by the presence of a permanent magnet. The recorded resistance curve is also shown in Fig. 1i. |
||
Date | |||
Source | Video file from Melzer M, Kaltenbrunner M, Makarov D, Karnaushenko D, Karnaushenko D, Sekitani T, Someya T, Schmidt O (2015). "Imperceptible magnetoelectronics". Nature Communications. DOI:10.1038/ncomms7080. PMID 25607534. PMC: 4354162. | ||
Author | Melzer M, Kaltenbrunner M, Makarov D, Karnaushenko D, Karnaushenko D, Sekitani T, Someya T, Schmidt O | ||
Permission (Reusing this file) |
This file is licensed under the Creative Commons Attribution 4.0 International license.
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 23:48, 1 November 2016 | 48 s, 640 × 480 (5.75 MB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Transcode status
Update transcode statusMetadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Short title | Supplementary Movie 3 |
---|---|
Author | Melzer M, Kaltenbrunner M, Makarov D, Karnaushenko D, Karnaushenko D, Sekitani T, Someya T, Schmidt O |
Usage terms | http://creativecommons.org/licenses/by/4.0/ |
Image title | Contacted magnetic field sensor on the palm and recorded resistance. This video demonstrates the compliancy of an on-skin sensor array (Co/Cu 1st maximum) attached to a human palm with one element contacted, together with its live recorded resistance. It shows that the resistance change during the motion of the hand is low compared to the change imposed by the presence of a permanent magnet. The recorded resistance curve is also shown in Fig. 1i. |
Software used | |
Date and time of digitizing |
|
Language | English |