File:Determination-of-a-New-Parameter-Elevated-Epiretinal-Membrane-by-En-Face-OCT-as-a-Prognostic-Factor-838646.f1.ogv
Determination-of-a-New-Parameter-Elevated-Epiretinal-Membrane-by-En-Face-OCT-as-a-Prognostic-Factor-838646.f1.ogv (Ogg multiplexed audio/video file, Theora/Vorbis, length 1 min 4 s, 428 × 240 pixels, 284 kbps overall, file size: 2.18 MB)
Captions
Summary
[edit]DescriptionDetermination-of-a-New-Parameter-Elevated-Epiretinal-Membrane-by-En-Face-OCT-as-a-Prognostic-Factor-838646.f1.ogv |
English: This video demonstrate the projection of the elevated membran areas (black pixels) on the retina image coming from the microscope. Based on this navigation membran peeling can be then initiated on the elevated membran areas without traumatising the retina. |
||
Date | |||
Source | Video file from Pavlidis M, Georgalas I, Körber N (2015). "Determination of a New Parameter, Elevated Epiretinal Membrane, by En Face OCT as a Prognostic Factor for Pars Plana Vitrectomy and Safer Epiretinal Membrane Peeling". Journal of Ophthalmology. DOI:10.1155/2015/838646. PMID 26504597. PMC: 4609466. | ||
Author | Pavlidis M, Georgalas I, Körber N | ||
Permission (Reusing this file) |
This file is licensed under the Creative Commons Attribution 3.0 Unported license.
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 19:45, 28 October 2015 | 1 min 4 s, 428 × 240 (2.18 MB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
The following 2 pages use this file:
Transcode status
Update transcode statusFile usage on other wikis
The following other wikis use this file:
- Usage on outreach.wikimedia.org
Metadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Author | Pavlidis M, Georgalas I, Körber N |
---|---|
Usage terms | http://creativecommons.org/licenses/by/3.0/ |
Image title |
|
Short title | EG-Report |
Software used | |
Date and time of digitizing |
|
Language | English |