File:Characterisation-of-the-dynamic-behaviour-of-lipid-droplets-in-the-early-mouse-embryo-using-1471-2121-11-38-S2.ogv
From Wikimedia Commons, the free media repository
Jump to navigation
Jump to search
No higher resolution available.
Characterisation-of-the-dynamic-behaviour-of-lipid-droplets-in-the-early-mouse-embryo-using-1471-2121-11-38-S2.ogv (Ogg Theora video file, length 9.5 s, 567 × 501 pixels, 801 kbps, file size: 926 KB)
File information
Structured data
Captions
Summary[edit]
DescriptionCharacterisation-of-the-dynamic-behaviour-of-lipid-droplets-in-the-early-mouse-embryo-using-1471-2121-11-38-S2.ogv |
English: SHG and THG image of mouse zygote. Opacity rendering of SHG (magenta) and THG (grey) image volumes of the surface of a mouse zygote. The meiotic spindle of the second polar body is visible in SHG. THG reveals LD and sperm. |
||
Date | |||
Source | Watanabe T, Thayil A, Jesacher A, Grieve K, Debarre D, Wilson T, Booth M, Srinivas S (2010). "Characterisation of the dynamic behaviour of lipid droplets in the early mouse embryo using adaptive harmonic generation microscopy". BMC Cell Biology. DOI:10.1186/1471-2121-11-38. PMID 20525231. PMC: 3238212. | ||
Author | Watanabe T, Thayil A, Jesacher A, Grieve K, Debarre D, Wilson T, Booth M, Srinivas S | ||
Permission (Reusing this file) |
This file is licensed under the Creative Commons Attribution 2.0 Generic license.
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 01:57, 21 November 2012 | 9.5 s, 567 × 501 (926 KB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Transcode status
Update transcode statusMetadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Short title | Additional file 2 |
---|---|
Author | Watanabe T, Thayil A, Jesacher A, Grieve K, Debarre D, Wilson T, Booth M, Srinivas S |
Usage terms | http://creativecommons.org/licenses/by/2.0/ |
Image title | SHG and THG image of mouse zygote. Opacity rendering of SHG (magenta) and THG (grey) image volumes of the surface of a mouse zygote. The meiotic spindle of the second polar body is visible in SHG. THG reveals LD and sperm. |
Software used | Xiph.Org libtheora 1.1 20090822 (Thusnelda) |
Date and time of digitizing | 2010 |