File:A-hydrophobic-barrier-deep-within-the-inner-pore-of-the-TWIK-1-K2P-potassium-channel-ncomms5377-s2.ogv
From Wikimedia Commons, the free media repository
Jump to navigation
Jump to search
No higher resolution available.
A-hydrophobic-barrier-deep-within-the-inner-pore-of-the-TWIK-1-K2P-potassium-channel-ncomms5377-s2.ogv (Ogg Theora video file, length 8.0 s, 480 × 480 pixels, 6.05 Mbps, file size: 5.77 MB)
File information
Structured data
Captions
Summary[edit]
DescriptionA-hydrophobic-barrier-deep-within-the-inner-pore-of-the-TWIK-1-K2P-potassium-channel-ncomms5377-s2.ogv |
English: Supplementary Movie 1 Dewetting of the TWIK-1 inner pore. Snapshots of water molecules (cyan) inside the inner pore of TWIK-1 channel taken every 0.1 ns during a 100 ns MD simulation. For orientation, the K+ ion at the bottom of the selectivity filter (S4) is shown as a purple sphere for orientation. Water loss is seen deep within the inner pore, but not at the cytoplasmic mouth of the channel. |
||
Date | |||
Source | Video file from Aryal P, Abd-Wahab F, Bucci G, Sansom M, Tucker S (2014). "A hydrophobic barrier deep within the inner pore of the TWIK-1 K2P potassium channel". Nature Communications. DOI:10.1038/ncomms5377. PMID 25001086. PMC: 4102122. | ||
Author | Aryal P, Abd-Wahab F, Bucci G, Sansom M, Tucker S | ||
Permission (Reusing this file) |
This file is licensed under the Creative Commons Attribution 4.0 International license.
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 14:43, 2 November 2016 | 8.0 s, 480 × 480 (5.77 MB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Transcode status
Update transcode statusMetadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Short title | Supplementary Movie 1 |
---|---|
Author | Aryal P, Abd-Wahab F, Bucci G, Sansom M, Tucker S |
Usage terms | http://creativecommons.org/licenses/by/4.0/ |
Image title | Dewetting of the TWIK-1 inner pore. Snapshots of water molecules (cyan) inside the inner pore of TWIK-1 channel taken every 0.1 ns during a 100 ns MD simulation. For orientation, the K+ ion at the bottom of the selectivity filter (S4) is shown as a purple sphere for orientation. Water loss is seen deep within the inner pore, but not at the cytoplasmic mouth of the channel. |
Software used | Xiph.Org libtheora 1.1 20090822 (Thusnelda) |
Date and time of digitizing | 2014-07-08 |