File:Spiral-Wave-Dynamics-in-a-Mathematical-Model-of-Human-Ventricular-Tissue-with-Myocytes-and-pone.0072950.s003.ogv
From Wikimedia Commons, the free media repository
Jump to navigation
Jump to search
Size of this JPG preview of this OGG file: 798 × 600 pixels. Other resolutions: 319 × 240 pixels | 639 × 480 pixels | 1,022 × 768 pixels | 1,200 × 902 pixels.
Original file (Ogg Theora video file, length 13 s, 1,200 × 902 pixels, 2.21 Mbps, file size: 3.29 MB)
File information
Structured data
Captions
Summary
[edit]DescriptionSpiral-Wave-Dynamics-in-a-Mathematical-Model-of-Human-Ventricular-Tissue-with-Myocytes-and-pone.0072950.s003.ogv |
English: Spiral-wave dynamics in our 2D homogeneous myocyte-fibroblast model with zero-sided coupling. (a) nS (control case, i.e., with only myocytes); (b) nS (low coupling); (c) nS (intermediate coupling); (d) nS (high coupling). Here spiral-tip trajectories, for , are shown by the white lines; we use 10 frames per second (fps); in real time each frame is separated from the succeeding frame by 8 ms. |
||
Date | |||
Source | Video S2 from Nayak A, Shajahan T, Panfilov A, Pandit R (2013). "Spiral-Wave Dynamics in a Mathematical Model of Human Ventricular Tissue with Myocytes and Fibroblasts". PLOS ONE. DOI:10.1371/journal.pone.0072950. PMID 24023798. PMC: 3762734. | ||
Author | Nayak A, Shajahan T, Panfilov A, Pandit R | ||
Permission (Reusing this file) |
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 19:43, 12 September 2013 | 13 s, 1,200 × 902 (3.29 MB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Transcode status
Update transcode statusMetadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Author | Nayak A, Shajahan T, Panfilov A, Pandit R |
---|---|
Usage terms | http://creativecommons.org/licenses/by/3.0/ |
Image title | Spiral-wave dynamics in our 2D homogeneous myocyte-fibroblast model with zero-sided coupling. (a) nS (control case, i.e., with only myocytes); (b) nS (low coupling); (c) nS (intermediate coupling); (d) nS (high coupling). Here spiral-tip trajectories, for , are shown by the white lines; we use 10 frames per second (fps); in real time each frame is separated from the succeeding frame by 8 ms. |
Software used | Xiph.Org libtheora 1.1 20090822 (Thusnelda) |
Date and time of digitizing | 2013 |