File:Echocardiographic-diagnosis-management-and-monitoring-of-pulmonary-embolism-with-right-heart-1476-7120-8-18-S2.ogv
Echocardiographic-diagnosis-management-and-monitoring-of-pulmonary-embolism-with-right-heart-1476-7120-8-18-S2.ogv (Ogg Theora video file, length 1.6 s, 640 × 480 pixels, 962 kbps, file size: 193 KB)
Captions
Summary
[edit]DescriptionEchocardiographic-diagnosis-management-and-monitoring-of-pulmonary-embolism-with-right-heart-1476-7120-8-18-S2.ogv |
English: Transthoracic echocardiogram (TTE) on admission. Apical 4-chamber view. |
||
Date | |||
Source | Hewing B, Ghaeni L, Dreger H, Fallenberg E, Panda A, Baumann G, Borges A (2010). "Echocardiographic diagnosis, management and monitoring of pulmonary embolism with right heart thrombus in a patient with myotonic dystrophy: a case report". Cardiovascular Ultrasound. DOI:10.1186/1476-7120-8-18. PMID 20470437. PMC: 2887806. | ||
Author | Hewing B, Ghaeni L, Dreger H, Fallenberg E, Panda A, Baumann G, Borges A | ||
Permission (Reusing this file) |
This file is licensed under the Creative Commons Attribution 2.0 Generic license.
|
||
Provenance InfoField |
|
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 03:29, 17 August 2013 | 1.6 s, 640 × 480 (193 KB) | Open Access Media Importer Bot (talk | contribs) | Automatically uploaded media file from Open Access source. Please report problems or suggestions here. |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Transcode status
Update transcode statusFile usage on other wikis
The following other wikis use this file:
- Usage on it.wikipedia.org
Metadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Short title | Additional file 2 |
---|---|
Author | Hewing B, Ghaeni L, Dreger H, Fallenberg E, Panda A, Baumann G, Borges A |
Usage terms | http://creativecommons.org/licenses/by/2.0/ |
Image title | Transthoracic echocardiogram (TTE) on admission. Apical 4-chamber view. |
Software used | Xiph.Org libtheora 1.1 20090822 (Thusnelda) |
Date and time of digitizing | 2010 |