DescriptionMeter bridge 001.jpg |
English: A meter bridge, also known as a slide wire bridge, is a simple and effective instrument used for measuring electrical resistance in a circuit. It consists of a one-meter-long wire mounted on a wooden or metallic base. The wire is usually made of a material with high electrical conductivity, such as constantan.
The meter bridge operates on the principle of a Wheatstone bridge, which balances the unknown resistance with a known resistance to determine the unknown resistance value. The bridge has a one-meter-long wire with a sliding jockey that can be moved along its length. A galvanometer is connected across the wire, and a known resistance is connected in series with the unknown resistance. By adjusting the position of the sliding jockey along the wire, the bridge is balanced when the galvanometer shows zero deflection. At this point, the ratio of the lengths of the wire on either side of the jockey is proportional to the ratio of the unknown resistance to the known resistance. This allows for the calculation of the unknown resistance based on the length of wire on either side of the jockey. The meter bridge is a versatile tool used in physics laboratories for educational purposes and practical experiments involving electrical circuits and resistance measurements.English: A meter bridge, also known as a slide wire bridge, is a simple and effective instrument used for measuring electrical resistance in a circuit. It consists of a one-meter-long wire mounted on a wooden or metallic base. The wire is usually made of a material with high electrical conductivity, such as constantan. The meter bridge operates on the principle of a Wheatstone bridge, which balances the unknown resistance with a known resistance to determine the unknown resistance value. The bridge has a one-meter-long wire with a sliding jockey that can be moved along its length. A galvanometer is connected across the wire, and a known resistance is connected in series with the unknown resistance. By adjusting the position of the sliding jockey along the wire, the bridge is balanced when the galvanometer shows zero deflection. At this point, the ratio of the lengths of the wire on either side of the jockey is proportional to the ratio of the unknown resistance to the known resistance. This allows for the calculation of the unknown resistance based on the length of wire on either side of the jockey. The meter bridge is a versatile tool used in physics laboratories for educational purposes and practical experiments involving electrical circuits and resistance measurements. |
Date | |
Source | Own work |
Author | Jeremyida002 |
Licensing[edit]
- You are free:
- to share – to copy, distribute and transmit the work
- to remix – to adapt the work
- Under the following conditions:
- attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
- share alike – If you remix, transform, or build upon the material, you must distribute your contributions under the same or compatible license as the original.
This file was uploaded as part of Wiki Science Competition 2023. |
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 16:08, 29 December 2023 | 3,104 × 3,104 (2.49 MB) | Jeremyida002 (talk | contribs) | Uploaded own work with UploadWizard |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Metadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Image title | |
---|---|
Camera manufacturer | TECNO MOBILE LIMITED |
Camera model | TECNO KE5 |
Exposure time | 39,999/1,000,000 sec (0.039999) |
F-number | f/1.8 |
ISO speed rating | 197 |
Date and time of data generation | 12:51, 14 December 2023 |
Lens focal length | 3.61 mm |
Orientation | Normal |
Horizontal resolution | 72 dpi |
Vertical resolution | 72 dpi |
Software used | Snapseed 2.0 |
File change date and time | 15:00, 29 December 2023 |
Y and C positioning | Co-sited |
Exposure Program | Not defined |
Exif version | 2.2 |
Date and time of digitizing | 12:51, 14 December 2023 |
Meaning of each component |
|
APEX exposure bias | 0 |
Metering mode | Center weighted average |
Light source | Other light source |
Flash | Flash did not fire |
DateTime subseconds | 58 |
DateTimeOriginal subseconds | 58 |
DateTimeDigitized subseconds | 58 |
Supported Flashpix version | 1 |
Color space | sRGB |
Exposure mode | Auto exposure |
White balance | Auto white balance |
Digital zoom ratio | 1 |
Focal length in 35 mm film | 0 mm |
Scene capture type | Standard |