File:X-ray tube 1.jpg

From Wikimedia Commons, the free media repository
Jump to navigation Jump to search

Original file(2,477 × 2,058 pixels, file size: 2.5 MB, MIME type: image/jpeg)

Captions

Captions

Add a one-line explanation of what this file represents
Description

Early Crookes x-ray tube from museum of Wilhelm Conrad Röntgen in Würzburg. The electrode on the lower left was the concave cathode, which focused a beam of electrons to a small (~1 mm) spot on the angled platinum anode in the center of the bulb, generating x-rays, which radiated through the forward wall of the tube toward the viewer. The electrode on the upper right was called the auxiliary anode. These early 'cold cathode' tubes were used from about 1900 to 1920.

The curved glass projection attached to the neck of the tube next to the cathode was a chemical 'softening' device to control the pressure in the tube. Crookes tubes required some air in the tube to operate. But over time the residual gas was absorbed by the walls, lowering the pressure. This required higher voltage across the tube, generating 'harder' x-rays, until the tube stopped working entirely. The softener contains either potassium chlorate or manganese dioxide. To restore the tube, the softener tube was heated in a flame, which released oxygen from the chemical, raising the pressure.
Date May 8th 2008 (see EXIF)
Source my own camera
Author me
Permission
(Reusing this file)
I, the copyright holder of this work, hereby publish it under the following licenses:
GNU head Permission is granted to copy, distribute and/or modify this document under the terms of the GNU Free Documentation License, Version 1.2 or any later version published by the Free Software Foundation; with no Invariant Sections, no Front-Cover Texts, and no Back-Cover Texts. A copy of the license is included in the section entitled GNU Free Documentation License.
w:en:Creative Commons
attribution share alike
This file is licensed under the Creative Commons Attribution-Share Alike 3.0 Unported, 2.5 Generic, 2.0 Generic and 1.0 Generic license.
You are free:
  • to share – to copy, distribute and transmit the work
  • to remix – to adapt the work
Under the following conditions:
  • attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
  • share alike – If you remix, transform, or build upon the material, you must distribute your contributions under the same or compatible license as the original.
You may select the license of your choice.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current22:07, 9 May 2008Thumbnail for version as of 22:07, 9 May 20082,477 × 2,058 (2.5 MB)Aida (talk | contribs){{Information |Description=Old X-ray tube from museum of Wilhelm Conrad Röntgen in Würzburg |Source=my own camera |Date=May 8th 2008 (see EXIF) |Author=me |Permission=Own work |other_versions= }} {{self|GFDL|cc-by-sa-3.0,2.5,2.0,1.0}} [[Category:X-ray

The following 2 pages use this file:

File usage on other wikis

The following other wikis use this file:

Metadata