[edit]DescriptionSpontaneous Raman hyperspectral imaging setup.svg |
English: A focused laser beam illuminates the sample at a given point in the sample plane (1). There, part of the Raman scattered light is collected by an objective (O). This collected light is spectrally filtered to discard laser light (dichroic filter (D) and notch filter (F2)); and spatially filtered with a confocal element (e.g., slit (S)). The frequency components contained in the Raman signal are then dispersed with a grating (G) onto a camera. A hyperspectral image is then obtained by repeating the procedure for each (x,y) coordinate of the sample plane. This is done by either scanning the sample stage (1) or the laser beam (2).
O: objective, M: mirror, L: lens (or other converging optics), D: dichroic mirror, S: slit, G: grating, F1: laser line filter, F2: notch filter
Français : Un faisceau laser est focalisé en un point donné de l’échantillon (1). Une partie du signal Raman diffusé est collecté par un objectif (O). Ce signal est séparé spectralement du signal Rayleigh et du signal émanant du laser par un miroir dichroïque (D) et un filtre coupe-bande (F2). Le filtrage spectral est assuré par un ou plusieurs éléments confocaux (ex. fente d’entrée (S)). Les composantes spectrales contenues dans le signal Raman sont ensuite séparées par un réseau de diffraction (G) et imagées sur une caméra. L’image hyperspectrale est finalement obtenue en mesurant un spectre Raman par coordonnée spatiale (x,y) de l’échantillon (par scan de le l’échantillon (1) ou du faisceau laser (2))
O: objectif, M: miroir, L: lentille (ou autre optique convergente), D: miroir dichroïque, S: fente, G: réseau, F1: filtre passe-bande laser, F2: filtre coupe-bande |
Date | |
Source | Own work |
Author | Camille Scotté |
Licensing
[edit]I, the copyright holder of this work, hereby publish it under the following license:
This file is licensed under the Creative Commons Attribution 4.0 International license.
- You are free:
- to share – to copy, distribute and transmit the work
- to remix – to adapt the work
- Under the following conditions:
- attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 20:26, 4 December 2021 | 440 × 201 (293 KB) | Cameeko (talk | contribs) | addition of Raman spectrum | |
20:06, 4 December 2021 | 440 × 201 (301 KB) | Cameeko (talk | contribs) | Uploaded own work with UploadWizard |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
File usage on other wikis
The following other wikis use this file:
- Usage on fa.wikipedia.org
Metadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
Width | 124.04728mm |
---|---|
Height | 56.598354mm |
Hidden categories: