File:Roentgen induction coils for quick work (1903) (14777939733).jpg

From Wikimedia Commons, the free media repository
Jump to navigation Jump to search

Original file(512 × 1,488 pixels, file size: 41 KB, MIME type: image/jpeg)

Captions

Captions

Add a one-line explanation of what this file represents

Summary

[edit]
Description
English:

Identifier: roentgeninductio00jame (find matches)
Title: Roentgen induction coils for quick work
Year: 1903 (1900s)
Authors: James G. Biddle Company
Subjects: X-rays Induction coils Radiography
Publisher: Philadelphia : James G. Biddle
Contributing Library: Francis A. Countway Library of Medicine
Digitizing Sponsor: Open Knowledge Commons and Harvard Medical School

View Book Page: Book Viewer
About This Book: Catalog Entry
View All Images: All Images From Book
Click here to view book online to see this illustration in context in a browseable online version of this book.

Text Appearing Before Image:
he anodes are adjusted to carry different amounts of current thecharacter of the discharge from the coil can be changed readily fromlight to heavy and vice versa by simply changing the position of theswitch. This modification is, in every other respect, like the usualform which is made with but one anode. It is provided with handles mounted on its wood case, makingit easily portable. The water cooling worm of lead tubing is just thesame as in the other form. The special hard porcelain construction of the anode is the same.The only difference in fact is the use of the three anodes, making itpossible to set them for light, medium and heavy discharges of thecoil respectively. After the anodes have once been adjusted, the dif-ferent kinds of discharge can be obtained by the manipulation of theswitches and the rheostat, the interrupter itself requiring no atten-tion. It may be placed in another room if desired. JAMES G. BIDDLE. II14 CHESTNUT STREET, PHILADELPHIA. Roentgen Series Spark Gap,
Text Appearing After Image:
Fig. 5. The well known phenomenon of the inverse discharge of theinduction coil makes it advisable to use some form of resistance inseries with the terminal of the induction coil and the X-Ray tube toprevent this inverse discharge from going through the tube. Whenthis inverse discharge is permitted to pass through the tube a black-ening of the inner walls of the tube occurs and is attributed to thedeposition of the metal of the electrodes upon the glass. The mostpractical form of resistance has been found to be a spark gap placedin series with the terminal of the induction coil and the tube, as theinverse discharge often is of sufficient voltage to jump across the re-sistance of an inch of air or more. If the series spark gap is greaterthan the distance through which the inverse discharge will jump itcannot pass into the tube and blacken it. The Roentgen series spark gap is readily adjusted to the top ofthe coil terminal by placing it in position, not requiring any bindingposts for mo

Note About Images

Please note that these images are extracted from scanned page images that may have been digitally enhanced for readability - coloration and appearance of these illustrations may not perfectly resemble the original work.
Date
Source

https://www.flickr.com/photos/internetarchivebookimages/14777939733/

Author Internet Archive Book Images
Permission
(Reusing this file)
At the time of upload, the image license was automatically confirmed using the Flickr API. For more information see Flickr API detail.
Flickr tags
InfoField
  • bookid:roentgeninductio00jame
  • bookyear:1903
  • bookdecade:1900
  • bookcentury:1900
  • bookauthor:James_G__Biddle_Company
  • booksubject:X_rays
  • booksubject:Induction_coils
  • booksubject:Radiography
  • bookpublisher:Philadelphia___James_G__Biddle
  • bookcontributor:Francis_A__Countway_Library_of_Medicine
  • booksponsor:Open_Knowledge_Commons_and_Harvard_Medical_School
  • bookleafnumber:15
  • bookcollection:medicalheritagelibrary
  • bookcollection:francisacountwaylibrary
  • bookcollection:americana
Flickr posted date
InfoField
27 July 2014

Licensing

[edit]
This image was taken from Flickr's The Commons. The uploading organization may have various reasons for determining that no known copyright restrictions exist, such as:
  1. The copyright is in the public domain because it has expired;
  2. The copyright was injected into the public domain for other reasons, such as failure to adhere to required formalities or conditions;
  3. The institution owns the copyright but is not interested in exercising control; or
  4. The institution has legal rights sufficient to authorize others to use the work without restrictions.

More information can be found at https://flickr.com/commons/usage/.


Please add additional copyright tags to this image if more specific information about copyright status can be determined. See Commons:Licensing for more information.
This image was originally posted to Flickr by Internet Archive Book Images at https://flickr.com/photos/126377022@N07/14777939733. It was reviewed on 16 September 2015 by FlickreviewR and was confirmed to be licensed under the terms of the No known copyright restrictions.

16 September 2015

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current15:40, 16 September 2015Thumbnail for version as of 15:40, 16 September 2015512 × 1,488 (41 KB) (talk | contribs)== {{int:filedesc}} == {{subst:chc}} {{information |description={{en|1=<br> '''Identifier''': roentgeninductio00jame ([https://commons.wikimedia.org/w/index.php?title=Special%3ASearch&profile=default&fulltext=Search&search=insource%3A%2Froentgeninducti...

There are no pages that use this file.