File:Radiography and radio-therapeutics (1917) (14757504802).jpg

From Wikimedia Commons, the free media repository
Jump to navigation Jump to search

Original file(1,984 × 2,994 pixels, file size: 480 KB, MIME type: image/jpeg)

Captions

Captions

Add a one-line explanation of what this file represents

Summary

[edit]
Description
English:

Identifier: radiographyradio01knox (find matches)
Title: Radiography and radio-therapeutics
Year: 1917 (1910s)
Authors: Knox, Robert, 1868-1928
Subjects: Radiography Radiotherapy
Publisher: New York : Macmillan
Contributing Library: University of California Libraries
Digitizing Sponsor: Internet Archive

View Book Page: Book Viewer
About This Book: Catalog Entry
View All Images: All Images From Book
Click here to view book online to see this illustration in context in a browseable online version of this book.

Text Appearing Before Image:
, shuwiiig switrli (-Zj. ami ^\vltl■ll-tul>le \vitli time \v).\\ ( 1),for using outfit as a rotating high-tension rectifier. Cabinet (3) contains single-impulsetransformer and rectifier, connected to an X-ray tube (1). portioned that the current may be adjusted from I milliampere to about80 milliamperes. When the apparatus is used for the taking of single-impulse radiogra))hsthe rotary rectifier is no longer used, hut only the high-voltage transformerbuilt into the apparatus. For single-impulse operation the transformer isno longer excited by the alternating current from the converter, but
Text Appearing After Image:
o ^it S, r- Ox,-3 2 • a c 3 SINGLE-IMPULSE A^D RAPID RADIOGRAPHY 53 obtains its current through the single-impulse switch from the continuouscurrent mains. The underlying principle of thesingle-impulsc method is briefly as follows:In the methods knowni hitherto, the current flowing through the primary wind-ing of the induction coil is suddenly interrupted after reaching its maximumintensity, i.e. at the moment when the iron core of the induction coil hasattained maximum saturation, and the result of the sudden disappearance ofthe flux is an inductive kick in the secondary winding. The force of thisinductive kick is considerably greater when the single-impulse methodis used inasmuch as the flux in the iron core does not merely drop from itsmaximum to zero but from a positive to a negative maximum. In con-sequence, the induction in the secondary wdnding must be particularlystrong, and the X-ray tube gives a flash of more than double the intensitythat would be obtained with a simple in

Note About Images

Please note that these images are extracted from scanned page images that may have been digitally enhanced for readability - coloration and appearance of these illustrations may not perfectly resemble the original work.
Date
Source

https://www.flickr.com/photos/internetarchivebookimages/14757504802/

Author Knox, Robert, 1868-1928
Permission
(Reusing this file)
At the time of upload, the image license was automatically confirmed using the Flickr API. For more information see Flickr API detail.
Flickr tags
InfoField
  • bookid:radiographyradio01knox
  • bookyear:1917
  • bookdecade:1910
  • bookcentury:1900
  • bookauthor:Knox__Robert__1868_1928
  • booksubject:Radiography
  • booksubject:Radiotherapy
  • bookpublisher:New_York___Macmillan
  • bookcontributor:University_of_California_Libraries
  • booksponsor:Internet_Archive
  • bookleafnumber:88
  • bookcollection:cdl
  • bookcollection:americana
Flickr posted date
InfoField
27 July 2014



Licensing

[edit]
This image was taken from Flickr's The Commons. The uploading organization may have various reasons for determining that no known copyright restrictions exist, such as:
  1. The copyright is in the public domain because it has expired;
  2. The copyright was injected into the public domain for other reasons, such as failure to adhere to required formalities or conditions;
  3. The institution owns the copyright but is not interested in exercising control; or
  4. The institution has legal rights sufficient to authorize others to use the work without restrictions.

More information can be found at https://flickr.com/commons/usage/.


Please add additional copyright tags to this image if more specific information about copyright status can be determined. See Commons:Licensing for more information.
This image was originally posted to Flickr by Internet Archive Book Images at https://flickr.com/photos/126377022@N07/14757504802. It was reviewed on 18 October 2015 by FlickreviewR and was confirmed to be licensed under the terms of the No known copyright restrictions.

18 October 2015

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current08:56, 18 October 2015Thumbnail for version as of 08:56, 18 October 20151,984 × 2,994 (480 KB) (talk | contribs)== {{int:filedesc}} == {{information |description={{en|1=<br> '''Identifier''': radiographyradio01knox ([https://commons.wikimedia.org/w/index.php?title=Special%3ASearch&profile=default&fulltext=Search&search=insource%3A%2Fradiographyradio01knox%2F fin...

There are no pages that use this file.