Description Intumescent firestop collar is applied at the bottom of the plastic pipe penetration. The problem is that the slab is not smooth and the fire can go straight through to the pipe above the collar.
Date
Source Own work
Author Achim Hering

Licensing

[edit]
Public domain This work has been released into the public domain by its author, I, Achim Hering. This applies worldwide.
In some countries this may not be legally possible; if so:
I, Achim Hering grants anyone the right to use this work for any purpose, without any conditions, unless such conditions are required by law.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current16:34, 25 December 2007Thumbnail for version as of 16:34, 25 December 20074,608 × 3,157 (1.57 MB)Achim Hering (talk | contribs){{Information |Description=Intumescent firestop collar is applied at the bottom of the plastic pipe penetration. The problem is that the slab is not smooth and the fire can go straight through to the pipe above the collar. |Source=own work |Date=1
16:32, 25 December 2007Thumbnail for version as of 16:32, 25 December 20074,608 × 3,157 (1.57 MB)Achim Hering (talk | contribs){{Information |Description=Intumescent firestop collar is applied at the bottom of the plastic pipe penetration. The problem is that the slab is not smooth and the fire can go straight through to the pipe above the collar. |Source=own work |Date=1
16:29, 25 December 2007Thumbnail for version as of 16:29, 25 December 20074,608 × 3,157 (1.57 MB)Achim Hering (talk | contribs){{Information |Description=Intumescent firestop collar is applied at the bottom of the plastic pipe penetration. The problem is that the slab is not smooth and the fire can go straight through to the pipe above the collar. |Source=own work |Date=1
04:03, 19 June 2007Thumbnail for version as of 04:03, 19 June 2007292 × 199 (46 KB)Achim Hering (talk | contribs){{Information |Description=Intumescent collar is applied at the bottom of the plastic pipe penetration. The problem is that the slab is not smooth and the fire can go straight through to the pipe above the collar. |Source=own work |Date=18. June 2007 |Aut

The following page uses this file:

Metadata