[edit]DescriptionFirestop mortar h2o ratio test 1 of 3.jpg | Firestop mortar being tested in Tulsa, Oklahoma in a 6" thick concrete wall, to see the effect of using different H2O:powder mix ratios on the same firestop. The test also confirmed that the mortar can be re-entered and re-sealed with the same firestop mortar. The test also demonstrated the effect of thermal shock on materials of different density while in contact with one another. The three hour fire endurance test was followed by a 30 PSI hose stream test for several minutes. A steel sleeve was used to narrow an opening. It was grouted in with firestop mortar. Then the inside of the steel sleeve was penetrated by a mineral foam insulated pipe and then sealed inside the sleeve with more firestop mortar. The hose stream test dislodged the interior mortar but 2" of the plug remained. The test passed. |
Date | |
Source | Own work |
Author | Achim Hering |
Licensing
[edit]I, the copyright holder of this work, hereby publish it under the following licenses:
Permission is granted to copy, distribute and/or modify this document under the terms of the GNU Free Documentation License, Version 1.2 or any later version published by the Free Software Foundation; with no Invariant Sections, no Front-Cover Texts, and no Back-Cover Texts. A copy of the license is included in the section entitled GNU Free Documentation License.http://www.gnu.org/copyleft/fdl.htmlGFDLGNU Free Documentation Licensetruetrue |
This file is licensed under the Creative Commons Attribution 3.0 Unported license.
- You are free:
- to share – to copy, distribute and transmit the work
- to remix – to adapt the work
- Under the following conditions:
- attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
You may select the license of your choice.
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 08:35, 9 December 2007 | 3,835 × 7,654 (2.4 MB) | Achim Hering (talk | contribs) | {{Information |Description=Firestop mortar being tested in Tulsa, Oklahoma in a 6" thick concrete wall, to see the effect of using different H2O:powder mix ratios on the same firestop. The test also confirme |
You cannot overwrite this file.
File usage on Commons
There are no pages that use this file.
Metadata
This file contains additional information such as Exif metadata which may have been added by the digital camera, scanner, or software program used to create or digitize it. If the file has been modified from its original state, some details such as the timestamp may not fully reflect those of the original file. The timestamp is only as accurate as the clock in the camera, and it may be completely wrong.
_error | 0 |
---|